How to replace the positioning ring of the temperature shock test chamber
release date:2015-09-01        Views:5        Back to list
Article Source
>High and Low Temperature Impact Test Chamber
>The temperature shock test chamber plays its role in many material industries. This equipment is used to test the ability of materials under continuous testing from high temperature to low temperature. How much can you bear? Moreover, positioning rings are required when testing this equipment, and these positioning rings need to be replaced. Next, the editor will introduce to you how to replace these positioning rings.
> The temperature shock test chamber needs to be kept clean during testing. Testers need to wear some clean disposable gloves before operating when they come into contact with the equipment. During testing, the positioning ring needs to be installed on the main shaft of the testing machine. There are
>
> positioning rings in total.
> When testing this equipment, a positioning ring needs to be replaced every time a test is performed. Each positioning ring is numbered, and these positioning rings require professional tools to be fixed in order to prevent the positioning ring from rotating due to testing. The back fixture of the positioning ring, the positioning ring and the front fixture of the positioning ring are fixed on the main shaft of the testing machine using professional screws.
> These positioning rings need to be inspected before each test. It is necessary to check whether there are scars, corrosion or surface abnormalities on the surface of these positioning rings. When these conditions occur, these positioning rings are damaged and can no longer be used for testing. At this time, new positioning rings must be replaced.
> When conducting tests in a temperature shock test chamber, in order to achieve the most accurate test data, the replacement of these rings is necessary, but if you feel that it is too wasteful to replace them with new ones every time, The old positioning ring can also be used, and the positioning ring can be installed this time according to the last record. More reading
>Thermal shock test chamber